Where to install carbon monoxide detectors in a Maryland home

CO alarms belong outside every sleeping area and on every level, with extra attention to gas furnaces, attached garages and generators. Here is where they go, and what Maryland and Harford County require.
Carbon monoxide alarm on a hallway wall outside bedrooms in a Maryland home

On this page

Short answer · 11 min read

Install a carbon monoxide detector in a central spot outside each separate sleeping area and on every level of the home, including the basement. Add one inside any bedroom that contains a fuel-burning appliance. Keep alarms out of garages, bathrooms and the spot right beside a furnace, and follow the manufacturer’s mounting instructions. Interconnected alarms give the best protection.

Key takeaways

Carbon monoxide is the hazard in our home electrical safety guide that you cannot see, smell or taste, which is why placement matters so much. The rule that covers most homes: one CO alarm in a central spot outside each sleeping area, one on every level, and extra care around fuel-burning appliances and attached garages.

Below we cover the standard placements, what Maryland’s CO alarm law and Harford County’s building code require, how gas furnaces, water heaters, attached garages and portable generators change the picture, where not to mount an alarm, and what to do the moment one sounds. If your home has no fuel-burning appliances and no attached garage, read on anyway: a generator in the driveway during an outage brings the same risk to an all-electric house.

Where should carbon monoxide detectors go in a house?

Carbon monoxide detectors go in a central location outside each separate sleeping area and on every level of the home, plus anywhere a law or code adds a location. That is NFPA’s guidance and the core of Maryland’s and Harford County’s rules. The goal is an alarm loud enough to wake every sleeper, close to where CO from a furnace, water heater or garage would travel.

CO alarm locations in a typical home

LocationWhy it mattersRequired or recommended
Hallway outside each group of bedroomsWakes sleepers, the people most at risk from CO at nightRequired in covered homes (state law and Harford County code)
Every level, including the basementCatches CO near basement furnaces and water heaters before it spreadsRequired in Maryland rentals; recommended by NFPA for all homes
Inside a bedroom with a fuel-fired applianceA gas fireplace or heater in the room puts the source next to the sleeperRequired by Harford County code (2021 IRC R315)
Near the door from an attached garageCar and generator exhaust can drift into the houseRecommended; garage is a trigger for alarms in Harford County
Finished basement bedroom or guest suiteTreat it like any other sleeping areaRequired where it is a sleeping area in a covered home
For the best protection, NFPA recommends interconnecting all CO alarms, so when one sounds they all sound. Interconnection works the same way as it does for smoke alarms: a third wire between hardwired units, or listed wireless alarms that signal each other.

What does Maryland law require for carbon monoxide alarms?

Maryland’s CO alarm law, Public Safety Article Title 12, Subtitle 11, covers new homes permitted on or after January 1, 2008 that burn fossil fuel, plus hotels, rooming houses and rental dwelling units. In those homes a CO alarm must be installed in a central location outside each sleeping area. Rentals have additional rules.
  • Which new homes: dwellings with a building permit issued on or after January 1, 2008 that rely on burning fossil fuel for heat, ventilation, hot water or clothes drying (Section 12-1102).
  • Rentals: since April 1, 2018, rental units need CO alarms outside and in the immediate vicinity of each separate sleeping area and on every level, including the basement (Section 12-1104(c)).
  • Power: owner-occupied covered homes need AC-powered alarms with battery backup. Rentals may also use sealed, tamper-resistant battery alarms with at least a 10-year battery life (Section 12-1101).
  • Central alarm systems: where a centralized system can sound a distinct alarm for every occupant, the owner may instead place a CO detector within 25 feet of any CO-producing fixture or equipment (Section 12-1104(d)).
  • Don’t disable them: except for routine maintenance, no one may make a CO alarm inoperable (Section 12-1105).

Harford County adds the attached garage

Harford County's building code follows Section R315 of the 2021 International Residential Code. Its CO alarm guidance (DILP Document 000162-2019, revised April 2026) requires alarms in new homes, and in homes getting a permit for alterations, repairs or additions, when the house has a fuel-fired appliance or an attached garage that opens into it. Alarms go outside each separate sleeping area near the bedrooms and inside any bedroom, or bedroom with an attached bath, that contains a fuel-fired appliance. Building inspectors check placement; electrical inspectors check the wiring. Exterior-only work such as roofing, siding, windows or a deck does not trigger the upgrade.

The practical upshot: if you are finishing a basement, adding a room or doing other permitted interior work in a Harford County home with gas heat or an attached garage, expect the inspector to look for CO alarms throughout the house, not only in the new space. The county guidance says those alarms take their main power from the house wiring with a battery backup, though battery-only units are allowed in some alteration cases. Other counties have their own adoptions, so your county inspector has the final word.

Where do CO detectors go near a gas furnace, water heater or fireplace?

Near fuel-burning appliances, a CO alarm goes in the same room or level but not right beside the appliance, at the spacing the alarm’s manual specifies. Appliances can release a brief puff of CO when they light, and an alarm mounted inches away may sound for no reason, which is how alarms end up unplugged.

Think about the path CO takes. A cracked heat exchanger or blocked flue on a basement furnace pushes exhaust into the basement first, then up the stairs and through the ductwork. An alarm on the basement level catches it early; the alarm outside the bedrooms catches it before it reaches sleepers.

Places to avoid

  • Inside the garage itself, where normal car starts can trigger it.
  • Directly above or beside a furnace, water heater, range or fireplace.
  • Bathrooms and laundry rooms, where steam and humidity can affect the sensor.
  • Next to windows, exterior doors, supply vents or ceiling fans that dilute the air reaching the sensor.
  • Dead air spots such as a ceiling peak or a corner where wall meets ceiling, unless the manual allows it.
  • Behind curtains or furniture that block air flow to the sensor.
CO weighs about the same as air and mixes through a room rather than sinking or rising sharply, so the right height depends on the model. Some alarms are made for the ceiling, some for the wall, and plug-in units sit at outlet height. NFPA’s advice is to follow the manufacturer’s instructions for placement and mounting height.
Combination smoke and CO alarm near the basement stairs with a furnace in the background
A combination smoke and CO alarm at the foot of the basement stairs, on the same level as the furnace but not beside it.

What we check on a CO alarm visit

We walk the house with you and note every fuel-burning appliance, the garage, the fireplace and where everyone sleeps. Then we check the age of any existing alarms, confirm hardwired units are on a working circuit with battery backup, and test that interconnected alarms sound together. A licensed HVAC or gas technician should inspect the appliances themselves.

Want a second set of eyes on your home’s wiring?

Text a photo or short video to 410-808-4215 and we’ll reply within 24 hours with what we see and what it means. Burning smell, sparks or a hot panel? Call now, day or night.

Do you need a CO detector if you have an attached garage or a generator?

Yes. An attached garage or a portable generator can bring carbon monoxide into an all-electric home, so a CO alarm is worth having even when nothing in the house burns fuel. Harford County’s code already treats an attached garage that opens into the house as a trigger for CO alarms in new and permitted remodeled homes.

Garage exhaust usually enters through the door to the kitchen or mudroom, gaps around that door, or shared ductwork. A car warming up for a few minutes on a January morning, or a mower started inside, is enough. NFPA advises moving a vehicle out of the garage right after starting it, even with the garage door open.
Electrician installing a carbon monoxide alarm beside the door to an attached garage
A CO alarm installed inside the house near the door to an attached garage.
Portable generators are the bigger danger during outages. Summer thunderstorms, nor’easters and ice storms knock out power across Harford, Baltimore and Cecil counties, and a generator running in a garage or under an open window can fill a house with CO within minutes. NFPA and Ready.gov both say to run generators outdoors at least 20 feet from doors, windows and vents, and never in an attached garage, even with the door open.
  • Point the generator’s exhaust away from the house.
  • Use a properly installed inlet and interlock or transfer switch, never a cord plugged into a dryer outlet. Backfeeding endangers BGE and Delmarva Power line crews as well as your family.
  • Keep the CO alarms in the house on battery backup so they work during the outage.
We install inlets and interlocks for Generac portable generators so the generator can sit at a safe distance and feed selected circuits through the panel. For why the dryer-cord shortcut is so dangerous, see never backfeed a generator.

Should a CO detector be hardwired, plug-in or battery?

A hardwired CO alarm with battery backup is the most reliable choice and is what Maryland law and Harford County code call for in covered owner-occupied homes. Plug-in and sealed battery alarms are good additions where no wiring exists, and rentals may use sealed 10-year battery units.

CO alarm types compared

TypeStrengthsWatch out for
Hardwired with battery backupSteady power, can interconnect with other alarms, works in an outage on its backup batteryNeeds a wired location; installed by an electrician
Combination smoke and CO (hardwired)One device per location, one interconnect systemMust be listed for both smoke and CO; follow both replacement schedules
Plug-in with battery backupEasy to add near bedrooms or the garage doorSits low, can be unplugged or blocked by furniture
Sealed 10-year batteryNo wiring, no battery swaps, allowed in Maryland rentalsNot a substitute where wired alarms are required
Whatever type you choose, look for a listing from a recognized testing laboratory. Harford County’s code text calls for CO alarms listed to UL 2034, and combination smoke and CO alarms listed to both UL 217 and UL 2034.

Hardwired CO and combination alarms are part of our carbon monoxide detector installation service. If you are replacing smoke alarms at the same time, the companion post on hardwired vs battery smoke detectors explains how to plan both systems together, and Maryland’s smoke alarm law sets its own rules for that side.

What should you do when a carbon monoxide alarm goes off?

When a CO alarm sounds, get everyone into fresh air right away, outdoors or at an open window or door, account for every person, and call 911 from that fresh-air location. Stay there until emergency responders say it is safe to go back in. Do not try to find the source first.

1

Move to fresh air

Go outside or to an open window or door. Bring pets if you can do it without delay.

2

Count heads

Make sure every person in the house is accounted for.

3

Call 911 from outside

Firefighters carry meters that measure CO levels and can find the source.

4

Stay out until cleared

Do not go back in to open windows or turn off appliances once you have left.

5

Get the source repaired

Have the furnace, water heater or other appliance checked by a qualified technician before using it again.

Symptoms count even without an alarm

Headache, dizziness, nausea, confusion or flu-like symptoms that ease when you leave the house are classic signs of CO exposure. If more than one person feels this way, leave and call 911 even if no alarm has sounded.

A single chirp at intervals is different. NFPA notes the trouble signal usually means a low battery; replace it, and if the chirping continues, the alarm may be at end of life or faulty. CO sensors wear out, so replace alarms on the schedule in the manufacturer’s instructions, and test them monthly along with your smoke alarms. Our fall and winter electrical checklist folds that test into the start of heating season, when furnaces come back on in Maryland homes.

Related reading

The 10-year rule, sealed battery alarms and what your home needs based on the year it was built.
How the two compare, and why interconnection matters in a multi-level house.
Heating-season checks for alarms, space heaters, holiday lights and storm outages.

FAQ

Questions homeowners ask

At a minimum, one outside each separate sleeping area and one on every level of the home, including the basement. A rancher with all bedrooms on one hall and a basement furnace usually needs two. A two-story colonial with a basement and an attached garage usually needs three or more. Add an alarm inside any bedroom with a fuel-burning appliance, and consider one near the garage door.
Some can and some cannot. Carbon monoxide mixes through the air in a room, so there is no single correct height, and each model is tested for specific mounting positions. Check the instructions: many combination smoke and CO alarms are made for the ceiling, while some CO-only alarms are made for the wall. NFPA recommends following the manufacturer’s placement and mounting-height instructions.
Maryland’s state law ties CO alarms in owner-occupied homes to fossil-fuel appliances, and Harford County adds an attached garage as a trigger. An all-electric home with a detached garage may not be required to have them. Many all-electric homeowners still add one, because a portable generator, a car in an attached garage or a neighbor’s exhaust can bring CO inside during an outage.
Yes. Since April 1, 2018, Maryland rental dwelling units have needed CO alarms outside and in the immediate vicinity of each separate sleeping area and on every level, including the basement. Landlords may use hardwired alarms with battery backup, sealed tamper-resistant battery alarms with at least a 10-year battery, or a monitored system. Tenants should not disable them except for routine maintenance.
CO sensors wear out, and most manufacturers set a replacement date between several years and a decade from manufacture. The date is printed on the alarm, and many models start an end-of-life chirp when it arrives. Replace the alarm when it reaches that date or chirps after a fresh battery, and test it monthly in the meantime. Combination units also follow the 10-year smoke alarm rule.
Michael Cliffe, owner of Snapper Electric

Reviewed for accuracy

Michael Cliffe, Owner · Maryland State Licensed Contractor, License 7788

Written by the Snapper Electric team · Last updated October 25, 2026

Electrical work can be dangerous. The information on this page is general guidance for homeowners in Maryland and is not a substitute for an on-site assessment by a licensed electrician. Always turn off power at the breaker before touching any wiring, and call 911 if you smell burning, see sparks, or have an active electrical fire.