Short answer · 11 min read
Key takeaways
- Put a CO alarm in a central location outside each sleeping area and on every level, including the basement.
- Maryland rentals have needed CO alarms outside each sleeping area and on every level since April 1, 2018.
- Harford County requires CO alarms in new and permitted remodeled homes with a fuel-fired appliance or an attached garage.
- Run portable generators outdoors at least 20 feet from doors, windows and vents, never in an attached garage.
- CO alarms do not replace smoke alarms. Combination units must be listed for both jobs.
Below we cover the standard placements, what Maryland’s CO alarm law and Harford County’s building code require, how gas furnaces, water heaters, attached garages and portable generators change the picture, where not to mount an alarm, and what to do the moment one sounds. If your home has no fuel-burning appliances and no attached garage, read on anyway: a generator in the driveway during an outage brings the same risk to an all-electric house.
Where should carbon monoxide detectors go in a house?
CO alarm locations in a typical home
| Location | Why it matters | Required or recommended |
|---|---|---|
| Hallway outside each group of bedrooms | Wakes sleepers, the people most at risk from CO at night | Required in covered homes (state law and Harford County code) |
| Every level, including the basement | Catches CO near basement furnaces and water heaters before it spreads | Required in Maryland rentals; recommended by NFPA for all homes |
| Inside a bedroom with a fuel-fired appliance | A gas fireplace or heater in the room puts the source next to the sleeper | Required by Harford County code (2021 IRC R315) |
| Near the door from an attached garage | Car and generator exhaust can drift into the house | Recommended; garage is a trigger for alarms in Harford County |
| Finished basement bedroom or guest suite | Treat it like any other sleeping area | Required where it is a sleeping area in a covered home |
What does Maryland law require for carbon monoxide alarms?
- Which new homes: dwellings with a building permit issued on or after January 1, 2008 that rely on burning fossil fuel for heat, ventilation, hot water or clothes drying (Section 12-1102).
- Rentals: since April 1, 2018, rental units need CO alarms outside and in the immediate vicinity of each separate sleeping area and on every level, including the basement (Section 12-1104(c)).
- Power: owner-occupied covered homes need AC-powered alarms with battery backup. Rentals may also use sealed, tamper-resistant battery alarms with at least a 10-year battery life (Section 12-1101).
- Central alarm systems: where a centralized system can sound a distinct alarm for every occupant, the owner may instead place a CO detector within 25 feet of any CO-producing fixture or equipment (Section 12-1104(d)).
- Don’t disable them: except for routine maintenance, no one may make a CO alarm inoperable (Section 12-1105).
Harford County adds the attached garage
Harford County's building code follows Section R315 of the 2021 International Residential Code. Its CO alarm guidance (DILP Document 000162-2019, revised April 2026) requires alarms in new homes, and in homes getting a permit for alterations, repairs or additions, when the house has a fuel-fired appliance or an attached garage that opens into it. Alarms go outside each separate sleeping area near the bedrooms and inside any bedroom, or bedroom with an attached bath, that contains a fuel-fired appliance. Building inspectors check placement; electrical inspectors check the wiring. Exterior-only work such as roofing, siding, windows or a deck does not trigger the upgrade.
Where do CO detectors go near a gas furnace, water heater or fireplace?
Think about the path CO takes. A cracked heat exchanger or blocked flue on a basement furnace pushes exhaust into the basement first, then up the stairs and through the ductwork. An alarm on the basement level catches it early; the alarm outside the bedrooms catches it before it reaches sleepers.
Places to avoid
- Inside the garage itself, where normal car starts can trigger it.
- Directly above or beside a furnace, water heater, range or fireplace.
- Bathrooms and laundry rooms, where steam and humidity can affect the sensor.
- Next to windows, exterior doors, supply vents or ceiling fans that dilute the air reaching the sensor.
- Dead air spots such as a ceiling peak or a corner where wall meets ceiling, unless the manual allows it.
- Behind curtains or furniture that block air flow to the sensor.
What we check on a CO alarm visit
We walk the house with you and note every fuel-burning appliance, the garage, the fireplace and where everyone sleeps. Then we check the age of any existing alarms, confirm hardwired units are on a working circuit with battery backup, and test that interconnected alarms sound together. A licensed HVAC or gas technician should inspect the appliances themselves.
Want a second set of eyes on your home’s wiring?
Do you need a CO detector if you have an attached garage or a generator?
Garage exhaust usually enters through the door to the kitchen or mudroom, gaps around that door, or shared ductwork. A car warming up for a few minutes on a January morning, or a mower started inside, is enough. NFPA advises moving a vehicle out of the garage right after starting it, even with the garage door open.
- Point the generator’s exhaust away from the house.
- Use a properly installed inlet and interlock or transfer switch, never a cord plugged into a dryer outlet. Backfeeding endangers BGE and Delmarva Power line crews as well as your family.
- Keep the CO alarms in the house on battery backup so they work during the outage.
Should a CO detector be hardwired, plug-in or battery?
CO alarm types compared
| Type | Strengths | Watch out for |
|---|---|---|
| Hardwired with battery backup | Steady power, can interconnect with other alarms, works in an outage on its backup battery | Needs a wired location; installed by an electrician |
| Combination smoke and CO (hardwired) | One device per location, one interconnect system | Must be listed for both smoke and CO; follow both replacement schedules |
| Plug-in with battery backup | Easy to add near bedrooms or the garage door | Sits low, can be unplugged or blocked by furniture |
| Sealed 10-year battery | No wiring, no battery swaps, allowed in Maryland rentals | Not a substitute where wired alarms are required |
Hardwired CO and combination alarms are part of our carbon monoxide detector installation service. If you are replacing smoke alarms at the same time, the companion post on hardwired vs battery smoke detectors explains how to plan both systems together, and Maryland’s smoke alarm law sets its own rules for that side.
What should you do when a carbon monoxide alarm goes off?
1
Move to fresh air
2
Count heads
3
Call 911 from outside
4
Stay out until cleared
5
Get the source repaired
Symptoms count even without an alarm
Headache, dizziness, nausea, confusion or flu-like symptoms that ease when you leave the house are classic signs of CO exposure. If more than one person feels this way, leave and call 911 even if no alarm has sounded.
Related reading
FAQ
Questions homeowners ask
How many carbon monoxide detectors do I need?
Can a CO detector go on the ceiling?
Do all-electric homes need carbon monoxide detectors?
Do Maryland landlords have to provide CO alarms?
How long do carbon monoxide detectors last?
Sources
- Maryland General Assembly: Public Safety Article, Section 12-1102 (CO alarm scope)
- Maryland General Assembly: Public Safety Article, Section 12-1104 (CO alarm placement)
- Maryland General Assembly: Public Safety Article, Section 12-1101 (definitions and power)
- Harford County DILP: Carbon Monoxide Alarm Requirements
- NFPA: Carbon monoxide safety tips
- Ready.gov: Power outages and generator safety