Half the house has no power: lost leg, open neutral or a breaker?

When some rooms go dark and others stay on, the cause is usually one of the two 120-volt legs feeding your home. Here is how to tell whose problem it is and what to do first.
Split-level home with lights on upstairs and the lower level dark during a partial power loss

On this page

Short answer · 12 min read

When half the house loses power, the most common cause is a lost leg: one of the two 120-volt lines feeding your panel has stopped delivering power. It can fail on the utility side (transformer, service drop, meter) or inside your service equipment (main breaker, lugs, meter socket). Check your neighbors and your main breaker, then call BGE or Delmarva Power if the problem is outside.

Key takeaways

Half the lights work, the kitchen outlets are dead, the dryer tumbles but never gets hot, and the breaker panel shows nothing tripped. This pattern has a short list of causes, and our electrical troubleshooting guide covers the rest of the symptom tree. The answer up front: a partial outage almost always means one of the two “legs” of power coming into your home has failed, either on the utility’s equipment or on yours.

The hard part is knowing who to call. The utility owns some of the parts involved and you own the rest. This post explains how split-phase power works in plain terms, how to tell a lost leg from a more dangerous open neutral, what you can check safely, and when to call BGE or Delmarva Power before you call an electrician.

Why would only half of my house lose power?

Only half the house loses power because your home is fed by two separate 120-volt lines, and one of them has stopped delivering. Electricians call each line a leg or a phase. Your panel alternates breakers between the two legs, so when one leg drops out, about half your 120-volt circuits go dead while the other half keep working.

This arrangement is called split-phase service. The utility transformer on the pole or the green pad in your yard sends three wires to the house: two hot legs and a neutral. Each leg measures about 120 volts to the neutral, and the two legs together measure about 240 volts. Lights and outlets use one leg. Large appliances such as an electric dryer, range, water heater, well pump or heat pump use both legs at once.

That is why a lost leg produces such a confusing mix. A bedroom on the healthy leg works normally. The bedroom next door on the dead leg is dark. The dryer drum may still turn, because its motor runs on 120 volts, while the heating element that needs 240 volts stays cold. A heat pump or central air unit usually stops completely.

What the pattern of dead circuits usually tells you

What you seeLikely causeWho to call first
About half the house dead, 240-volt appliances not heating, neighbors also affectedLost leg on the utility side (transformer fuse, drop, connection)BGE or Delmarva Power
About half the house dead, neighbors fine, no storm damage visibleLost leg at the meter socket, service cable, main breaker or main lugsUtility to check the meter side, then a licensed electrician
Some lights very bright, others dim, bulbs or electronics failingOpen or loose neutralTurn off the main, then call the utility and an electrician right away
One room or a few outlets dead, rest of the house normalA single circuit: tripped breaker, GFCI or a loose connectionReset once, then an electrician
Everything deadFull outage or main breaker trippedUtility outage line; check the main breaker
If only one room or a handful of outlets are out, that is a single-circuit problem rather than a lost leg. Our post on an outlet not working when the breaker is not tripped walks through that one.

Lost leg or open neutral: how can you tell the difference?

You can usually tell them apart by what the working lights do. With a lost leg, the circuits that still work behave normally and the dead ones are fully dead. With an open neutral, nothing is cleanly dead: lights on one side of the house glow brighter than normal while lights on the other side dim, and the pattern shifts when a large load such as the microwave or a hair dryer turns on.

The neutral is the return path that keeps each leg at a steady 120 volts. If it breaks or works loose at the transformer, the meter socket or the main panel, the two legs are left in series across 240 volts. The voltage then divides according to whatever happens to be plugged in. One side might see 160 volts or more while the other drops to 80. Electronics, LED drivers and appliance control boards on the high side can be damaged within minutes.

Stop and call if lights are surging bright and dim

Lights that flare unusually bright, bulbs that pop, electronics that shut off or smell hot, or a buzzing panel are signs of an open neutral. Turn off the main breaker if you can reach it safely and dry-handed, unplug expensive electronics, and call your utility's emergency line. If you smell burning or see smoke or sparks at the meter or panel, leave the house and call 911 first.

A loose neutral rarely announces itself all at once. It often starts as flicker when the air conditioner or well pump starts, which is why lights that flicker or dim when an appliance turns on deserve attention before they turn into a partial outage.

Why both problems often start outside

Overhead service connections take wind, ice load and tree contact for decades. A split-bolt or compression connector at the point where the utility’s drop meets your service cable can corrode or loosen until it opens one conductor. Underground services fail too, usually at splices or where a cable was nicked years ago. Either way, the fault can sit on either side of the ownership line, which is why the next question matters.

Should you call BGE or Delmarva Power before an electrician?

Call the utility first when the problem could be on its equipment: your neighbors also have partial power, a storm just passed, a tree is on the line, the overhead drop is sagging or torn loose, or the meter itself looks damaged. The utility can test at the meter and either fix its side or confirm the problem is on yours, and it costs you nothing to ask.

As a general rule, Maryland utilities own the transformer, the service drop or underground lateral up to the connection point, and the meter. The homeowner typically owns the service mast and weatherhead, the service entrance cable, the meter socket (the base the meter plugs into), the main breaker and everything inside the panel. BGE and Delmarva Power each publish their own equipment-responsibility rules, so confirm the line at your address when you call.

Maryland: who serves you and how to report it

Most of Harford and Baltimore counties are BGE territory. Report an outage or partial power at 1-877-778-2222, by texting OUT to 69243, or online at bge.com. Cecil County is served by Delmarva Power: call 1-800-898-8042 or use delmarva.com. Your electric bill names your utility. Maryland regulation COMAR 20.50.07.02 requires the utility to keep 120/240-volt residential service between 114/228 and 126/252 volts at the service terminals, outside of storms and brief fluctuations, so a missing leg at the meter is the utility's to fix. Numbers as of October 2026; confirm on the utility's site.

Tell the utility exactly what you see: “About half the house is out, the dryer runs but won’t heat, the neighbors are fine.” That wording helps the dispatcher send a troubleshooter instead of logging a routine outage.

If the utility tests the meter and finds both legs healthy on its side, the fault is inside your service equipment. That is when you call a licensed electrician. Snapper Electric keeps a 24/7 emergency electrician line for exactly this situation, because a home running on one leg cannot run heat, hot water or a well pump for long.

Still tripping, flickering or dead after the safe checks?

Text a photo or short video to 410-808-4215 and we’ll reply within 24 hours with what we see and what it means. Burning smell, sparks or a hot panel? Call now, day or night.

What can you safely check yourself when part of the house is out?

You can safely check four things without opening any electrical equipment: whether the neighbors have power, whether any breaker is tripped, whether the main breaker is fully on, and what the overhead line looks like from the ground. Stop there. The meter, the meter socket and the inside of the panel are not homeowner territory.

1

Look outside first

Check whether neighbors on the same transformer have the same problem. If they do, call the utility and wait.

2

Scan the panel without removing the cover

Look for any breaker handle sitting in the middle or off position. A tripped two-pole breaker can kill one side of a 240-volt appliance.

3

Cycle the main breaker once

With dry hands and dry footing, push the main breaker firmly to OFF, then back to ON. A main that has partly tripped will sometimes restore the dead leg. Do this once only.

4

Note which rooms are dead

A quick list of dead rooms and appliances helps the utility or the electrician confirm a lost leg in minutes instead of hours.

5

Look at the service drop from the ground

Note sagging wires, a torn mast, a tree limb on the line or scorch marks near the meter. Stay well away from any wire that is down or low and assume it is live.

6

Protect electronics

Unplug computers, TVs and other sensitive electronics until power is fully restored, especially if any lights were flaring bright.
Do not pull the meter, do not remove the panel cover and do not try to move circuits from the dead leg to the live one. Those steps put you in contact with conductors that stay energized even with the main breaker off, because the wires feeding the main breaker cannot be switched off from inside the house.

What causes a lost leg on the homeowner's side of the meter?

On the homeowner’s side, a lost leg usually comes from a failed main breaker pole, a loose or corroded main lug, a burned jaw in the meter socket, or damaged service entrance cable. Each of these is a heat problem at heart: a connection that loosened over years, ran hot, oxidized and finally opened.
  • Main breaker failure. A two-pole main breaker is really two breakers tied together. Internal contacts on one pole can burn open while the other pole keeps working.
  • Loose service lugs. The large set screws that clamp the service conductors can loosen with years of heating and cooling, especially on aluminum service entrance cable common in 1960s through 1980s homes. A loose lug heats, discolors and eventually stops conducting.
  • Meter socket jaws. The spring jaws that grip the meter blades can weaken or burn. A melted or discolored meter base is a sign of this, and it is a job for the utility and an electrician together.
  • Service entrance cable damage. Weathered cable jackets, water entering at the weatherhead or a nail through the cable on the way into the house can open one conductor.
  • Problem panels. Some older panels are known for poor breaker-to-bus contact; see our post on Federal Pacific Stab-Lok panel replacement.
Older meter socket with heat discoloration and weathered service entrance cable on a brick wall
A discolored meter socket and weathered service cable are typical places a lost leg starts on the homeowner's side.

What an electrician checks

We measure each leg to neutral and leg to leg at the main breaker's line and load side to see where voltage disappears, look for heat damage on lugs and breaker stabs, and often scan the panel with a thermal imaging camera to find connections running hot before they fail. An on-site check confirms the cause; nobody can diagnose a lost leg for certain over the phone.

Many Harford County homes are 1960s and 1970s split-levels and ranchers, and plenty still run on their original service equipment. In those homes, a partial outage is often the first sign the panel or service is near the end of its life. These failures often show up after a hot spell, when air conditioning has kept old connections loaded for days. Our Harford County electricians check the whole service, not just the part that failed.

How is a lost leg repaired, and does it need a permit?

The repair depends on where the fault is. A failed main breaker gets replaced. A loose lug gets cleaned or replaced and torqued to the manufacturer’s specification. A burned meter socket or damaged service entrance cable means replacing that part of the service, which requires coordination with the utility to disconnect and reconnect power.

Service equipment work usually requires an electrical permit and inspection before the utility will restore full service. In Harford County, electrical permits go through the Electrical Services division at the Permit Center, 220 S. Main Street in Bel Air, and must be applied for by an electrician holding a Harford County master license (homeowners can get a one-time permit for their own home after passing a test). The county enforces the 2023 National Electrical Code as adopted in 2024, with local amendments. We pull the permit when the job requires one, and the county inspector has the final word on code questions.

If the panel itself is the problem, a replacement may be the safer path than repairing one burned component. Our panel installation and repair page explains what that involves, and a repair that keeps an aging panel going is sometimes reasonable as a stopgap. We explain both options and the tradeoffs before any work starts.

Common lost-leg repairs and what they involve

Fault foundTypical fixUtility involved?
Failed main breaker poleReplace the main breaker or panelSometimes, to de-energize the service
Loose or burned main lugsClean, replace and torque connections; repair damaged bus if possibleUsually, to de-energize the service
Burned meter socket jawReplace the meter socketYes, the utility pulls and resets the meter
Damaged service entrance cable or weatherheadReplace the cable, mast or weatherheadYes, the utility disconnects and reconnects the drop
Utility connection or transformerUtility repairYes, no electrician needed

Related reading

Loose neutrals and utility-side voltage problems often show up as flicker first.
Causes, safe resets and when a tripping breaker points to a bigger problem.
What panel noises mean and how a thermal imaging check finds hot connections.

FAQ

Questions homeowners ask

You can use the working circuits for a short time if the lights on them look normal, but it is not a long-term arrangement. Heat pumps, well pumps, electric water heaters and ranges will not work, and a partly failed connection keeps heating as it carries load. If any lights are flaring bright, that is an open neutral rather than a lost leg, and you should turn off the main and call right away.
The dryer’s motor and controls run on 120 volts from one leg, while the heating element needs 240 volts across both legs. When one leg is lost, the drum can still turn but the element gets nothing. A range with an electric oven or a water heater behaves the same way. That symptom is one of the quickest ways to confirm a lost leg rather than a single tripped circuit.
Reporting partial power to BGE or Delmarva Power is part of normal outage reporting, and the utility tests its own equipment at the meter. If the fault is on the utility side, the utility repairs it. If the fault is on your side of the connection point, the utility will tell you to call a licensed electrician. Ask the utility about any charges for special trips when you call, since policies can change.
A clean lost leg usually just stops things from working. The bigger risk is an open neutral, where some circuits see well above 120 volts and electronics, LED bulbs and appliance control boards can fail. Motors on a partially powered 240-volt circuit can also overheat if they try to start repeatedly. Unplug sensitive electronics and turn off the main breaker if voltage seems unstable.
Coverage depends on your policy and on whether the damage is sudden or the result of age and wear. Many policies treat gradual deterioration differently from storm damage such as a tree pulling down the service. Take photos before repairs, keep the electrician’s written findings, and ask your agent. We can document what we find so you have it for the claim.

Sources

Codes, programs and fees change. We checked these sources in October 2026; confirm current details with the agency or utility.
Michael Cliffe, owner of Snapper Electric

Reviewed for accuracy

Michael Cliffe, Owner · Maryland State Licensed Contractor, License 7788

Written by the Snapper Electric team · Last updated October 25, 2026

Electrical work can be dangerous. The information on this page is general guidance for homeowners in Maryland and is not a substitute for an on-site assessment by a licensed electrician. Always turn off power at the breaker before touching any wiring, and call 911 if you smell burning, see sparks, or have an active electrical fire.