Short answer · 11 min read
Key takeaways
- A short dip under one second when a motor starts is usually normal; repeated or lasting flicker is not.
- Lights getting brighter in some rooms and dimmer in others is a classic sign of a loose or broken neutral.
- A loose neutral can push some outlets well above 120 volts and damage electronics.
- If neighbors' lights flicker too, or flicker follows wind, call BGE or Delmarva Power first.
- Flicker in only one fixture is usually the bulb, the dimmer or a connection at that light.
This post explains why lights dip, how to tell a harmless dip from a warning sign, what a loose neutral is and why it is urgent, how to decide whether the problem belongs to BGE or Delmarva Power or to your house wiring, and what an electrician measures to find the cause. If you see lights turning very bright, smell burning or hear crackling, skip ahead to the warning box.
Why do lights dim when an appliance turns on?
Every wire has a little resistance. When current rises, voltage drops across that resistance, and the lights on the same circuit or the same service see slightly less voltage for a moment. The usual suspects are central air conditioners and heat pumps, refrigerators and freezers, well pumps, sump pumps, washing machines, vacuum cleaners, microwaves and laser printers.
A brief dip like this is normal when it is short (well under a second), small (a slight dimming, not near-darkness), and tied to one obvious appliance starting. Utilities in the United States generally aim to keep a 120-volt service within about 5 percent, roughly 114 to 126 volts, under the ANSI C84.1 standard, and a short startup sag can dip below that without anything being wrong.
LED bulbs can make dips more noticeable. Some LEDs, especially on older dimmers, react to small voltage changes with a visible flicker where an incandescent bulb would have dimmed smoothly. That is a compatibility issue, not a wiring fault, and it is covered below.
When is flickering normal, and when is it a warning?
Flicker patterns and what they usually mean
| Pattern | Likely cause | Urgency and who to call |
|---|---|---|
| Brief dip when the A/C, fridge or pump starts | Normal inrush current on a shared circuit or service | Low. Note it; mention it at your next service visit. |
| Deep dip every time the A/C starts, getting worse each summer | Hard-starting compressor, undersized wiring or a weak service connection | Moderate. HVAC check plus electrician. |
| One fixture or lamp flickers | Loose bulb, failing LED, incompatible dimmer or loose connection at that light | Low to moderate. Try another bulb, then electrician. |
| Lights in one room or on one circuit flicker | Loose connection at a switch, outlet, splice or breaker | Moderate. Electrician soon. |
| Lights flicker all over the house, with no clear trigger | Loose connection in the panel, meter base or service conductors | High. Call an electrician today. |
| Some lights bright, others dim, appliances acting odd | Loose or open neutral | Urgent. Turn off sensitive electronics and call the utility and an electrician now. |
| Neighbors’ lights flicker too, or flicker follows wind or storms | Utility-side issue: transformer, service drop or connection | Call BGE or Delmarva Power first. |
What is a loose neutral, and why is it dangerous?
Most Maryland homes get split-phase service: two hot conductors, each 120 volts to the neutral, and 240 volts between them. Your 120-volt circuits are split between the two hots, and the neutral carries the difference in load between them back to the transformer. With a solid neutral, each side stays near 120 volts no matter how unevenly loaded it is.
If that neutral connection loosens, the two halves of the house become two loads in series across 240 volts. The lightly loaded side can rise toward 140 or 150 volts while the heavily loaded side sags toward 90. Turn on a space heater on one side and the lights on the other side flare. Electronics, LED drivers, chargers and appliance control boards are not built for that and can fail.
Stop and call if you notice any of these
Lights that go very bright, bulbs burning out in several fixtures at once, appliances or electronics shutting off or failing, a burning smell, buzzing at the panel or meter, or a warm panel cover. Unplug sensitive electronics, turn off large loads, and call. If you see sparks or smoke at the meter or panel, or a service wire is down, stay away and call 911 and your utility first.
Still tripping, flickering or dead after the safe checks?
Is it BGE's problem or your house wiring?
In general, the utility owns the transformer, the service drop or underground service lateral up to your service point, and the meter. The homeowner owns the service mast and weatherhead on overhead services, the meter base, the service entrance conductors, the panel and everything after it. Exact ownership lines vary by utility and by installation, so BGE or Delmarva Power can confirm the split for your address.
Who to call in Harford, Baltimore and Cecil counties
Most of Harford County and all of Baltimore County are served by BGE, which takes outage and electric problem reports 24/7 at 1-877-778-2222 and lists 1-800-685-0123 for electric emergencies such as downed wires. Cecil County is served by Delmarva Power, which takes reports 24/7 at 1-800-898-8042; a small part of northern Harford near the Pennsylvania line may also be Delmarva territory. Tell them your lights are flickering or brightening house-wide. If they find their side is fine, the next call is an electrician.
What causes flicker in only one fixture or room?
- Bulb: tighten it, then swap in a bulb from a fixture that works. Cheap LEDs often fail by flickering first.
- Dimmer compatibility: older incandescent dimmers often cause LED flicker or buzzing at low settings. An LED-rated dimmer usually fixes it.
- Switch or fixture connection: if the flicker changes when you tap the switch plate or the fixture, a connection is loose. Turn it off and call.
- Shared circuit: if one room flickers when a window unit or space heater runs, that circuit may be overloaded or have a loose splice.
What can you safely check before calling?
1
Note the pattern
2
Swap a bulb
3
Check with a neighbor
4
Look, do not touch
5
Protect electronics
6
Call the right party
How does an electrician find the cause of flickering?
What we check on a flicker call
Voltage at the panel on each leg, at rest and with large loads running; leg-to-leg and neutral readings that reveal an imbalance; thermal imaging of the main lugs, neutral bar and breakers; torque on service and branch connections; the condition of the meter base, mast and service entrance cable; and the switch, fixture or outlet connections on the circuit that flickers. For intermittent problems, a power quality analyzer can record voltage over days.
For flicker anywhere from Bel Air to the Cecil County line, our fast electrical repairs team can usually get you on the schedule quickly. Call or text 410-808-4215, and use the 24/7 line if lights are flaring bright or you smell burning.
Related reading
FAQ